Holzweide 6
28307 Bremen
Deutschland
Telefon: +49 (0) 421 / 48 99 66
Telefax: +49 (0) 421 / 48 99 699
E-Mail:
Produktübersicht
Inhalationshilfe LiteAir Spacer
Art.Nr.: 60-1114
HMV-Nr.:
Gewicht: 0kg
T: 0mm B: 0mm H: 0mm
Keine Bewertungen
Beschreibung
LiteAire Spacer 25 Stück VPE
Ultraleichte, faltbare Pocket-Inhalationshilfe
Die einfache Alternative zum Plastik-Spacer für
unterwegs – auf dem Sportplatz, im Zug oder Auto etc.
- Hemdtaschengröße – nur 13g leicht, faltbar
- Für alle Standard-MDI´s einsetzbar
- Bessere Deposition
Berichte/Literatur
In Vitro Comparison of Albuterol Dose Output for Standard MDI with LiteAire Spacer versus Misty Max 10 Nebulizer
Sunil Dhuper MD, Sanjay Arora MD, Aziz Ahmed MD, Alpana Chandra MD ,Cynthia Chong MD, Chang Shim MD, Hillel Cohen Dr Ph, Scott Foss, Sonia Choksi MD
Sunil Dhuper, Coney Island Hospital: 2601 Ocean Parkway, Brooklyn, NY, USA, 11235
.....Conclusion
We recommend using 6 albuterol MDI actuations with the LiteAire spacer when conducting a clinical efficacy study as the in vitro dose outputs using 6 MDI actuations and a unit dose of nebulizer are comparable. However, a controlled study comparing the two modes of treatment in patients with asthma would be desirable to demonstrate equivalent clinical efficacy.
Download: In Vitrao Comparison of Albuterol Dose ......
EFFICACY AND COST COMPARISONS OF BRONCHODILATOR ADMINISTRATION BETWEEN MDI’S WITH A DISPOSABLE SPACER AND NEBULIZER FOR ACUTE ASTHMA TREATMENT
Sunil Dhuper MD, Alpana Chandra MD, Aziz Ahmed MD, Sabin Bista MD, Ajit Moghekar MD, Rajesh Verma MD, Cynthia Chong MD, Chang Shim MD, Hillel Cohen Dr. PH, Sonia Choksi MD
Coney Island Hospital: 2601 Ocean Parkway, Brooklyn, NY, USA, 11235
Conclusion
We found that in a busy, municipal hospital ER, bronchodilator therapy for adults with acute exacerbation of asthma can be administered just as efficaciously using the LiteAire device as with a conventional nebulizer.Additionally, it may result in savings in time and effort invested by the respiratory therapist and consequently a savings in total cost for treatment.
Download: EFFICACY AND COST COMPARISONS OF BRONCHODILATOR ADMINISTRATION BETWEEN MDI’S.......
Metered-dose inhaler output comparison between a collapsible paperboard holding chamber and two rigid plastic chambers
Carl Okeson, Ph.D., Paul McGowen, RRT Thayer Medical Corporation, Tucson, Arizona, USA, AARC 2006: 52nd International Respiratory Congress, Las Vegas, NV. December 11-14, 2006
Respiratory Care; November 2006, Vol. 51, No. 11, pg. 1322
Conclusions
Under the conditions tested, the paperboard LiteAire provided drug delivery performance that was either statistically equivalent to or superior to the rigid plastic VHCs evaluated. Based on these results, the LiteAire appears to offer an effective, lower cost alternative to plastic holding chambers, particularly for singlepatient, single-use applications.
Download: Metered-dose inhaler output comparison between a collapsible paperboard.....